|P260 Pressure Reducing Valve
|PHP30 Pressure Reducing Valve
|PPD41-3 Pressure Reducing Valve|
|B260 Back Pressure Regulating Valve
| |
|
■P260 Pressure Reducing Valve (845KB) |
|
For general steam line
Size : 15〜250A
P1 : 0.1〜3.0MPa
P2 : 0.03〜2.5MPa
Max. temperature : 184, 220, 240, 260, 300℃
Material : | BodyーFC, FCD, SCPH, SCS |
Valve disc/seatーSUS |
Connection : Flanged
• | For steam, most reputable Pressure Reducing Valve |
• | Wide range of sizes from 15A to 250A |
• | No chattering, No vibration even for High-Low differential pressure. |
• | Light and compact |
| |
|
| | |
|
|
■PHP30 Pressure Reducing Valve (254KB) |
|
For high pressure, high temperature
Size : 25〜100A
P1 : 0.3〜4.0MPa
P2 : 0.1〜2.5MPa
Max. temperature : 300, 370℃
Material : | BodyーSCPH |
Valve disc/seatーSUS (special) |
Connection : Flanged
• | Withstand big differential pressure and cope with large fluctuation of flow. |
• | Strong construction No damage even if inlet pressure is loaded to outlet side. |
| |
|
| | |
|
|
■PPD41-3 Pressure Reducing Valve (437KB) |
|
For small flow rate
Size : 15〜25A
P1 : 0.05〜1.6MPa
P2 : 0.03〜0.7MPa
Max. temperature : 220℃
Material : | BodyーFC, SCPH, SCS |
Valve disc/seatーSUS |
Connection : Screwed, Flanged
• | Compact design for small flow rate |
• | Sharp response to pressure fluctuation.
|
• | Free ball type inner valve made of wear-resistant material. |
• | Heat-resistant rubber diaphragm |
| |
|
| | |
|
|
■B260 Back Pressure Regulating Valve (699KB) |
|
For general steam line
Size : 15〜80A
P1 : 0.07〜1.0MPa
Max. temperature : 220℃
Material : | BodyーFC |
Valve disc/seatーSUS |
Connection : Flanged
• | Large capacity |
• | Can be used for continuous discharge. |
| |
|
| | |
|
|
To the top of this page |
|